Hotline:
+86 15542446883
Solar cable
Application:
This product is suitable for connecting indoor and outdoor solar photovoltaic system circuits under extreme weather conditions
Standard:
2PfG 1169/08.2007 (PV1-F)
Structure:
Conductor: Stranded tinned copper wire in accordance with DIN VDE 0295 and IEC 60228 Class 5
Insulation: electron beam cross-linking, low smoke halogen-free flame retardant composite
Sheath: electron beam cross-linked, low smoke halogen-free flame retardant composite, black
Electrical performance:
Rated voltage U0/U: 0.6/1 kV AC; 0.9/1.5 kV DC
Maximum allowable AC voltage: 1.8 kV DC (conductor/conductor, ungrounded system, circuit without load)
Insulation resistance: 1000 MΩ-km
Spark test: 6000 Vac (8400 Vdc)
Voltage endurance: 6500 Vac for 5 min
Thermal performance:
Indoor temperature:- 40℃ ~ +90℃
Maximum temperature of conductor: IEC/EN 60216-1 120℃ (20000h)
Short circuit temperature: 200℃/5 s
Heat resistance test: EN 60216-2 (temperature+120 ° C)
High temperature pressure test: EN 60811-3-1
Moisture and heat resistance: EN60068-2-78, 85% humidity
Mechanical properties:
Minimum bending radius: 4×OD (fixed), 5×OD (flexing)
Dynamic penetration: 2 PfG 1169/08.2007 Appendix F
Slot propagation: 2 PfG 1169/08.2007 Appendix G
Tensile strength and elongation of insulation layer and sheath: EN 60811
Expected service life: 25 years
CHEMICAL:
Ozone resistance: EN 50396 Part 8.1.3 Method B
Weathering and UV resistance: HD 605/A1
Ammonia resistant
Good resistance to oil and chemical corrosion
Good wear resistance and aging resistance
Acid and alkali resistance: according to EN 60811-2-1 (oxalic acid&sodium hydroxide)
EC indicators:
This cable complies with CE 2006/95/EC (low voltage regulations) and RoHS 2002/95/EC (regulations restricting the use of hazardous substances) in European standards
Fire performance:
Flame retardant performance specified in EN 50265-2-1, IEC 60332-1, VDE 0482-332-1-2, DIN EN 60332-1-2
Low smoke performance specified in IEC 61034, EN 50268
Halogen free performance specified in EN 50267-2-1, IEC 60754-1
Low corrosive gases specified in EN 50267-2-2 and IEC 60754-2
Specifications and dimensions:
current carrying capacity:
Conversion coefficient deviating from temperature:
CONTACT US
Shengdong Cable Co., Ltd
Phone:+86 15542446883
Email:alladu0399@gmail.com
Address:713, Unit 52, Beiyi West Road,
Tiexi District,Shenyang City,
Liaoning Province ,China

MESSAGE
CONTACT US
Shengdong Cable Co., Ltd
Phone:+86 15542446883
Email:alladu0399@gmail.com
Address:713, Unit 52, Beiyi West Road, Tiexi District,
Shenyang City, Liaoning Province ,China
MESSAGE